一、產品概述
IHG立式不銹鋼管道泵性能好、可靠性高、壽命長、結構合理、 外形美觀
二、用 途
IHG型立式單級單吸化工泵,供輸送不含固體顆粒,具有腐蝕性,粘度類似于水的液體,適用于石油、化工、冶金、電力、造紙、食口制藥等部門,使用溫度為-20℃~+105℃。
型號意義:
不銹鋼管道離心泵性能參數表
泵型號 | 流量 | 揚程 (m) |
效率 (%) |
轉速 (r/min) |
電機功率 (kw) |
汽蝕佘量 (m) |
|
---|---|---|---|---|---|---|---|
(m 3 /h) | (l/s) | ||||||
15-80 | 1.5 | 0.42 | 8 | 34 | 2800 | 0.18 | 2.3 |
20-110 | 2.5 | 0.69 | 15 | 34 | 2800 | 0.37 | 2.3 |
20-160 | 2.5 | 0.69 | 32 | 25 | 2900 | 0.75 | 2.3 |
25-110 | 4 | 1.11 | 15 | 42 | 2900 | 0.55 | 2.3 |
25-125 | 4 | 1.11 | 20 | 36 | 2900 | 0.75 | 2.3 |
25-125A | 3.6 | 1.0 | 16 | 35 | 2900 | 0.55 | 2.3 |
25-160 | 4 | 1.11 | 32 | 32 | 2900 | 1.5 | 2.3 |
25-160A | 3.7 | 1.03 | 28 | 31 | 2900 | 1.1 | 2.3 |
32-125 | 5 | 1.39 | 20 | 44 | 2900 | 0.75 | 2.3 |
32-125A | 4.5 | 1.25 | 16 | 43 | 2900 | 0.5 | 2.3 |
40-100 | 6.3 | 1.75 | 12.5 | 54 | 2900 | 0.55 | 2.3 |
40-100A | 5.6 | 1.56 | 10 | 52 | 2900 | 0.37 | 2.3 |
40-125 | 6.3 | 1.75 | 20 | 46 | 2900 | 1.1 | 2.3 |
40-125A | 5.6 | 1.56 | 16 | 45 | 2900 | 0.75 | 2.3 |
40-160 | 6.3 | 1.75 | 32 | 40 | 2900 | 2.2 | 2.3 |
40-160A | 5.9 | 1.64 | 28 | 39 | 2900 | 1.5 | 2.3 |
40-160B | 5.5 | 1.53 | 24 | 38 | 2900 | 1.1 | 2.3 |
40-200 | 6.3 | 1.75 | 50 | 33 | 2900 | 4.0 | 2.3 |
40-200A | 5.9 | 1.64 | 44 | 31 | 2900 | 3.0 | 2.3 |
40-200B | 5.3 | 1.47 | 36 | 29 | 2900 | 2.2 | 2.3 |
40-250 | 6.3 | 1.75 | 80 | 28 | 2900 | 7.5 | 2.3 |
40-250A | 5.9 | 1.64 | 70 | 28 | 2900 | 5.5 | 2.3 |
40-250B | 5.5 | 1.53 | 60 | 27 | 2900 | 4.0 | 2.3 |
40-100(I) | 12.5 | 3.47 | 12.5 | 62 | 2900 | 1.1 | 2.3 |
40-100(I)A | 11 | 3.05 | 10 | 60 | 2900 | 0.75 | 2.3 |
40-125(I) | 12.5 | 3.47 | 20 | 58 | 2900 | 1.5 | 2.3 |
40-125(I)A | 11 | 3.05 | 16 | 57 | 2900 | 1.1 | 2.3 |
40-160(I) | 12.5 | 3.47 | 32 | 52 | 2900 | 3.0 | 2.3 |
40-160(I)A | 11.7 | 3.25 | 28 | 51 | 2900 | 2.2 | 2.3 |
40-160(I)B | 10.4 | 2.89 | 22 | 50 | 2900 | 1.5 | 2.3 |
40-200(I) | 12.5 | 3.47 | 50 | 46 | 2800 | 5.5 | 2.3 |
40-200(I)A | 11.7 | 3.25 | 44 | 45 | 2900 | 4.0 | 2.3 |
40-200(I)B | 10.6 | 2.94 | 36 | 44 | 2900 | 3 | 2.3 |
40-250(I) | 12.5 | 3.47 | 80 | 38 | 2900 | 11 | 2.3 |
40-250(I)A | 11.6 | 3.22 | 70 | 38 | 2900 | 7.5 | 2.3 |
40-250(I)B | 10.8 | 3.0 | 60 | 37 | 2900 | 7.5 | 2.3 |
40-250(I)C | 10.0 | 2.78 | 52 | 36 | 2900 | 5.5 | 2.3 |
50-100 | 12.5 | 3.47 | 12.5 | 62 | 2900 | 1.1 | 2.3 |
50-100A | 11 | 3.05 | 10 | 60 | 2900 | 0.75 | 2.3 |
50-125 | 12.5 | 3.47 | 20 | 58 | 2900 | 1.5 | 2.3 |
50-125A | 11 | 3.05 | 16 | 57 | 2900 | 1.1 | 2.3 |
50-160 | 12.5 | 3.47 | 32 | 52 | 2900 | 3.0 | 2.3 |
50-160A | 11.7 | 3.25 | 28 | 51 | 2900 | 2.2 | 2.3 |
50-160B | 10.4 | 2.89 | 22 | 50 | 2900 | 1.5 | 2.3 |
50-200 | 12.5 | 3.47 | 50 | 46 | 2900 | 5.5 | 2.3 |
50-200A | 11.7 | 3.25 | 44 | 45 | 2900 | 4.0 | 2.3 |
50-200B | 10.6 | 2.94 | 36 | 44 | 2900 | 3 | 2.3 |
50-250 | 12.5 | 3.47 | 80 | 38 | 2900 | 11 | 2.3 |
50-250A | 11.6 | 3.22 | 70 | 38 | 2900 | 7.5 | 2.3 |
50-250B | 10.8 | 3.0 | 60 | 37 | 2900 | 7.5 | 2.3 |
50-250C | 10.0 | 2.78 | 52 | 36 | 2900 | 5.5 | 2.3 |
50-100(I) | 25 | 6.94 | 12.5 | 69 | 2900 | 1.5 | 2.5 |
50-100(I)A | 22.3 | 6.19 | 10 | 67 | 2900 | 1.1 | 2.5 |
50-125(I) | 25 | 6.94 | 20 | 68 | 2900 | 3.0 | 2.5 |
50-125(I)A | 22.3 | 6.19 | 16 | 66 | 2900 | 2.2 | 2.5 |
50-160(I) | 25 | 6.94 | 32 | 63 | 2900 | 4.0 | 2.5 |
50-160(I)A | 23.4 | 6.5 | 28 | 62 | 2900 | 4.0 | 2.5 |
50-160(I)B | 21.6 | 6.0 | 24 | 58 | 2900 | 3.0 | 2.5 |
50-200(I) | 25 | 6.94 | 50 | 58 | 2900 | 7.5 | 2.5 |
50-200(I)A | 23.5 | 6.53 | 44 | 57 | 2900 | 7.5 | 2.5 |
50-200(I)B | 21.8 | 6.06 | 38 | 55 | 2900 | 5.5 | 2.5 |
50-250(I) | 25 | 6.94 | 80 | 50 | 2900 | 15 | 2.5 |
50-250(I)A | 23.4 | 6.5 | 70 | 50 | 2900 | 11 | 2.5 |
50-250(I)B | 21.6 | 6.0 | 60 | 49 | 2900 | 11 | 2.5 |
50-315(I) | 25 | 6.94 | 125 | 40 | 2900 | 30 | 2.5 |
50-315(I)A | 23.7 | 6.58 | 113 | 40 | 2900 | 22 | 2.5 |
50-315(I)B | 22.5 | 6.25 | 101 | 39 | 2900 | 18.5 | 2.5 |
50-315(I)C | 20.6 | 5.72 | 85 | 38 | 2900 | 15 | 2.5 |
故障原因 | 排除方法 | |
1、水泵不出水 | a、進出口閥門未打開,進出管路堵塞,流道葉輪堵塞; | a、檢查,去除堵塞物; |
b、電機運行方向不對,電機缺相轉速很慢; | b、調整電機方向,緊固電機接線。 | |
c、吸入管漏氣; | c、擰緊各密封面,排除漏氣; | |
d、泵沒灌滿液體,泵腔內有空氣; | d、灌滿液體并打開排氣閥,排盡空氣; | |
e、進口供水不足,吸程過高,底閥漏水; | e、停機,檢查、調整(并網自來水管或帶吸程使用易出現此現象); | |
f、管路阻力過大,泵選型不當。 | f、減少管路彎道,重新選泵。 | |
2、水泵流量不足 | a、先按1.原因檢查; | a、先按1.排除。 |
b、管道、泵流道葉輪部分堵塞,水垢陳積,閥門開度不足; | b、去除堵塞物,重新調整閥門開度; | |
c、電壓偏低; | c、穩壓; | |
d、葉輪磨損。 | d、更換葉輪; | |
3、功率過大 | a、超過額定流量使用; | a、調節流量,關小出口閥門; |
b、吸程過高; | b、降低; | |
c、泵軸承磨損; | c、更換軸承; | |
4、雜音振動 | a、管路支撐不穩; | a、穩固管路; |
b、液體混有氣體; | b、提高吸入壓力排氣; | |
c、產生汽蝕; | c、降低真空度; | |
d、軸承損壞; | d、更換軸承; | |
e、電機超載發熱運行。 | e、調整按5; | |
5、電機發熱 | a、流量過大,超載運行; | a、關小出口閥; |
b、碰擦; | b、檢查排除; | |
c、電機軸承損壞; | c、更換軸承; | |
d、電壓不足; | d、穩壓; | |
6、水泵漏水 | a、機械密封磨損; | a、更換; |
b、泵體有砂孔或破裂; | b、焊補或更換; | |
c、密封面不平整; | c、修整; | |
d、安裝螺栓松懈; | d、緊固; |